1000 Kg H Boiler Water Capacity

  • Offshore price : $20000-$100000 Get a quote on the right form
  • Minimum order quantity : 1 set :1000 Kg H Boiler Water Capacity
  • Supply Capacity : 10 units/month :1000 Kg H Boiler Water Capacity
  • Manufacturer/Brand : Fangkuai boiler
  • Port : Anyang
  • payment terms : Letter of Credit, Wire Transfer, VISA

Leave Your Message And Get Price!

I need the quotation of , the fuel is , this capacity is , use for . My Name is , my Email is , my WhatsApp is , Please Send the detail information for me!

Popular products

HOT

θrion Gas Fired Steam Boiler

Capacity:1-20t/h

Rated thermal efficiency: 100-104%

Fixed working pressure: ≤1.6MPa

Applicable fuel:natural gas etc.

consult
HOT

Gas(oil) Fired Integrated Hot Water Boiler

Capacity:0.7-14MW

Rated thermal efficiency:96-98%

Fixed working pressure:≤1.25MPa

Applicable fuel:Natural gas, light oil, etc.

consult
HOT

H6 Gas Fired Hot Water Boiler

Capacity:0.7-2.8Mw

Rated thermal efficiency: 97.2-106%

Fixed working pressure:0.1MPa

Applicable fuel:Natural gas, etc.

consult
HOT

T7 Vacuum Hot Water Boilerr

Capacity:2.8-7.0Mw

Rated thermal efficiency:≥105.5%

Fixed working pressure:-0.02MPa

Applicable fuel:Natural gas, etc.

consult
HOT

V6 Gas Fired Hot Water Boiler

Capacity:99Kw

Rated thermal efficiency:97.2-104.4%

Fixed working pressure:1.0MPa

Applicable fuel:Natural gas, etc.

consult
HOT

Electric Steam Boiler

Capacity:0.5-4.0 t/h

Rated thermal efficiency:98%

Fixed working pressure:≤1.25MPa

Applicable fuel:electric energy

consult

Leave us a message

We will send out plans and quotations within five minutes

Name (optional)

Email

Whatsapp

Choose product type

Message

boilermanufactory

Get display discount

boiler
Contact us

Global Sales Hotline:
0086-371-60922096

Email: [email protected]

Voicemail
  • Automatic Coal- Fired Boiler – Providing heat when you

    These furnaces use coal to provide you warmth and efficiency. Cleaning are available for all Keystoker products.; 365/24/7 emergency services and repair parts help your boiler running.; Finding a replacement for your boiler doesn't have to be a headache.Get Price

  • Boiler Capacity - Engineering ToolBox

    Since the amount of steam delivered varies with temperature and pressure, a common expression of the boiler capacity is the heat transferred over time expressed as British Thermal Units per hour. A boilers capacity is usually expressed as kBtu/hour (1000 Btu/hour) and can be calculated as. W = (h g - h f) m (1)Get Price

  • Water Treatment Plant Capacity Calculation

    Jan 28, 2017 · I don't have experience in calculating demineralized water demand for amine contactor or chemical dilution. So, in this post, I assume demineralized water is used as boiler feed water. Let say we have boiler with capacity of 10 ton/hour. Assume blow down rate is 3%. Demin water demand is = (1+3%) x 10 ton/hour = 10.3 ton/hour. Assuming Get Price

  • Boiler Efficiency - an overview | ScienceDirect Topics

    The boiler manufacturer should state the maximum total dissolved solids (TDS) in the boiler water at which the required steam purity can be obtained. The steam as measured at drum outlet should have an impurity not greater than 0.02 mg/kg (ppm mass) silica.Get Price

  • PROCESS DESIGN OF WATER SYSTEMS (PROJECT …

    exhaust air, units: kg per hour or percent of circulating water flow. Feedwater - The water supplied to a boiler to make-up for losses. Floc - Any small, tufted, or flakelike mass of matter floating in a solution, e.g., as produced by precipitation. Fresh Water - Water having less than approximately 1,000 mg/L of dissolved matter.Get Price

  • Boiler Efficiency - an overview | ScienceDirect Topics

    The boiler manufacturer should state the maximum total dissolved solids (TDS) in the boiler water at which the required steam purity can be obtained. The steam as measured at drum outlet should have an impurity not greater than 0.02 mg/kg (ppm mass) silica.Get Price

  • Water-tube boiler - Wikipedia

    A high pressure watertube boiler (also spelled water-tube and water tube) is a type of boiler in which water circulates in tubes heated externally by the fire. Fuel is burned inside the furnace, creating hot gas which boils water in the steam-generating tubes.In smaller boilers, additional generating tubes are separate in the furnace, while larger utility boilers rely on the water-filled …Get Price

  • uniSTOR | Cylinders | Vaillant UK

    Vaillant uniSTOR unvented cylinders can be used when converting from an open vented system (with a cold water tank in the loft) to a sealed system (boiler and cylinder system). Converting to a sealed system can help save space e.g. during loft conversions etc when there is no room for a tank, and in most cases will provide higher water pressure Get Price

  • Water-tube boiler - Wikipedia

    A high pressure watertube boiler (also spelled water-tube and water tube) is a type of boiler in which water circulates in tubes heated externally by the fire. Fuel is burned inside the furnace, creating hot gas which boils water in the steam-generating tubes.In smaller boilers, additional generating tubes are separate in the furnace, while larger utility boilers rely on the water-filled …Get Price

  • PROCESS DESIGN OF WATER SYSTEMS (PROJECT …

    exhaust air, units: kg per hour or percent of circulating water flow. Feedwater - The water supplied to a boiler to make-up for losses. Floc - Any small, tufted, or flakelike mass of matter floating in a solution, e.g., as produced by precipitation. Fresh Water - Water having less than approximately 1,000 mg/L of dissolved matter.Get Price

  • Water Treatment Plant Capacity Calculation

    Jan 28, 2017 · I don't have experience in calculating demineralized water demand for amine contactor or chemical dilution. So, in this post, I assume demineralized water is used as boiler feed water. Let say we have boiler with capacity of 10 ton/hour. Assume blow down rate is 3%. Demin water demand is = (1+3%) x 10 ton/hour = 10.3 ton/hour. Assuming Get Price

  • Boiler Capacity - Engineering ToolBox

    Since the amount of steam delivered varies with temperature and pressure, a common expression of the boiler capacity is the heat transferred over time expressed as British Thermal Units per hour. A boilers capacity is usually expressed as kBtu/hour (1000 Btu/hour) and can be calculated as. W = (h g - h f) m (1)Get Price

  • Boiler - Wikipedia

    Q, rate of steam flow in kg/h Hg, enthalpy of saturated steam in kcal/kg Hf, enthalpy of feed water in kcal/kg q, rate of fuel use in kg/h GCV, gross calorific value in kcal/kg (e.g., pet coke 8200 kcal/kg) Heat-loss method (or, indirect method) To measure the boiler efficiency in indirect method, parameter like these are neededGet Price

  • Boiler - Wikipedia

    Q, rate of steam flow in kg/h Hg, enthalpy of saturated steam in kcal/kg Hf, enthalpy of feed water in kcal/kg q, rate of fuel use in kg/h GCV, gross calorific value in kcal/kg (e.g., pet coke 8200 kcal/kg) Heat-loss method (or, indirect method) To measure the boiler efficiency in indirect method, parameter like these are neededGet Price

  • Boiler Capacity - Engineering ToolBox

    Since the amount of steam delivered varies with temperature and pressure, a common expression of the boiler capacity is the heat transferred over time expressed as British Thermal Units per hour. A boilers capacity is usually expressed as kBtu/hour (1000 Btu/hour) and can be calculated as. W = (h g - h f) m (1)Get Price

  • Water Treatment Plant Capacity Calculation

    Jan 28, 2017 · I don't have experience in calculating demineralized water demand for amine contactor or chemical dilution. So, in this post, I assume demineralized water is used as boiler feed water. Let say we have boiler with capacity of 10 ton/hour. Assume blow down rate is 3%. Demin water demand is = (1+3%) x 10 ton/hour = 10.3 ton/hour. Assuming Get Price

  • uniSTOR | Cylinders | Vaillant UK

    Vaillant uniSTOR unvented cylinders can be used when converting from an open vented system (with a cold water tank in the loft) to a sealed system (boiler and cylinder system). Converting to a sealed system can help save space e.g. during loft conversions etc when there is no room for a tank, and in most cases will provide higher water pressure Get Price

  • Automatic Coal- Fired Boiler – Providing heat when you

    These furnaces use coal to provide you warmth and efficiency. Cleaning are available for all Keystoker products.; 365/24/7 emergency services and repair parts help your boiler running.; Finding a replacement for your boiler doesn't have to be a headache.Get Price

  • PROCESS DESIGN OF WATER SYSTEMS (PROJECT …

    exhaust air, units: kg per hour or percent of circulating water flow. Feedwater - The water supplied to a boiler to make-up for losses. Floc - Any small, tufted, or flakelike mass of matter floating in a solution, e.g., as produced by precipitation. Fresh Water - Water having less than approximately 1,000 mg/L of dissolved matter.Get Price

  • Boiler Efficiency - an overview | ScienceDirect Topics

    The boiler manufacturer should state the maximum total dissolved solids (TDS) in the boiler water at which the required steam purity can be obtained. The steam as measured at drum outlet should have an impurity not greater than 0.02 mg/kg (ppm mass) silica.Get Price

  • uniSTOR | Cylinders | Vaillant UK

    Vaillant uniSTOR unvented cylinders can be used when converting from an open vented system (with a cold water tank in the loft) to a sealed system (boiler and cylinder system). Converting to a sealed system can help save space e.g. during loft conversions etc when there is no room for a tank, and in most cases will provide higher water pressure Get Price

  • Biogas from Manure

    Mar 05, 2012 · After condensing any water vapor in the biogas, the gas can be used as fuel in stoves, water heaters, and boilers. However, the gas burner nozzle must be enlarged to compensate for the low-Btu gas. Tests using biogas as the only fuel in a gasoline engine showed that the energy in 200 cubic feet (5.7 m 3 ) of biogas equaled the energy in 1 Get Price

  • Automatic Coal- Fired Boiler – Providing heat when you

    These furnaces use coal to provide you warmth and efficiency. Cleaning are available for all Keystoker products.; 365/24/7 emergency services and repair parts help your boiler running.; Finding a replacement for your boiler doesn't have to be a headache.Get Price

  • Water-tube boiler - Wikipedia

    A high pressure watertube boiler (also spelled water-tube and water tube) is a type of boiler in which water circulates in tubes heated externally by the fire. Fuel is burned inside the furnace, creating hot gas which boils water in the steam-generating tubes.In smaller boilers, additional generating tubes are separate in the furnace, while larger utility boilers rely on the water-filled …Get Price

  • Boiler - Wikipedia

    Q, rate of steam flow in kg/h Hg, enthalpy of saturated steam in kcal/kg Hf, enthalpy of feed water in kcal/kg q, rate of fuel use in kg/h GCV, gross calorific value in kcal/kg (e.g., pet coke 8200 kcal/kg) Heat-loss method (or, indirect method) To measure the boiler efficiency in indirect method, parameter like these are neededGet Price

Discount
7X24 Online