Used Steam Boilers With Pressure 10 0 15 0
Capacity:1-20t/h
Rated thermal efficiency: 100-104%
Fixed working pressure: ≤1.6MPa
Applicable fuel:natural gas etc.
Capacity:0.7-14MW
Rated thermal efficiency:96-98%
Fixed working pressure:≤1.25MPa
Applicable fuel:Natural gas, light oil, etc.
Capacity:0.7-2.8Mw
Rated thermal efficiency: 97.2-106%
Fixed working pressure:0.1MPa
Applicable fuel:Natural gas, etc.
Capacity:2.8-7.0Mw
Rated thermal efficiency:≥105.5%
Fixed working pressure:-0.02MPa
Applicable fuel:Natural gas, etc.
Capacity:99Kw
Rated thermal efficiency:97.2-104.4%
Fixed working pressure:1.0MPa
Applicable fuel:Natural gas, etc.
Capacity:0.5-4.0 t/h
Rated thermal efficiency:98%
Fixed working pressure:≤1.25MPa
Applicable fuel:electric energy
Jul 12, 2009 · Masteel supply high quality carbon steel plate for boiler and pressure vessel fabrication which is ideally suited to the high standards set by the oil, gas and petrochemical industry - this is why we stock an extensive range of carbon plates according to ASTM A516 Grade 70 and ASME SA516 Grade 70.Get Price
Feb 19, 2015 · There are a number of considerations to factor when determining the best boiler for your steam generation needs like operating pressure, steam pounds/hour output, demand fluctuation, general application requirments and total cost of ownership, etc. Two primary boiler types, the firetube boiler and the watertube boiler, are essentially opposite in design. The …Get Price
PROCESS DESIGN OF STEAM BOILERS (PROJECT STANDARDS AND SPECIFICATIONS) Page 8 of 45 Rev: 01 April 2011 i. The steam as measured at drum outlet shall have an impurity not greater than 0.02 mg/kg (ppm mass) silica. The wetness of the steam leaving the drum shall not exceed 0.02%. j. Heat release (maximum and average) per cubic meters of furnace Get Price
Steam Output. Steam output from the Torripac boiler range is from 1 000 kg/h to 13 000 kg/h. Design pressures of up to 32 bar are available to be used in conjunction with saturated steam screw expanders for cogeneration applications. For higher power outputs, superheaters can be incorporated into the design for use with steam turbines.Get Price
* Steam capacities shown are saturated steam. Capacities will vary depending on conditions and limitations. Metric Conversions: inches x 25.4 = mm. inches x 2.54 = cm. feet x 0.3048 = m. lb/h x 0.000453 = T/h. lb/h x 0.000126 = kg/sGet Price
Because the operating temperature, pressure, and form of heat distribution are different from hot water heat (typically 20-30 psi of hot water), steam boilers (typically less than 0.5 psi steam) use use controls that monitor steam pressure operated controls like the Honeywell steam pressure control shown below.Get Price
10 a: 60: 5.0: 9.0: PB pipe or tubing: 2.67: 4: PEX tubing: 2.67: 4: PP less than 1-inch pipe: 2.67: 4: PP more than 1 ¼ inches: 4: 10 a: PVC: 4: 10 a: Steel pipe: 12: 15: Steel tubing: 8: 10 a: a For sizes 2 inches and smaller, a guide should be installed midway between required vertical supports. Such guides should prevent pipe movement in a Get Price
Boilers can be classified into the following configurations: Pot boiler or Haycock boiler/Haystack boiler A primitive "kettle" where a fire heats a partially filled water container from below. 18th century Haycock boilers generally produced and stored large volumes of very low-pressure steam, often hardly above that of the atmosphere.Get Price
Oct 16, 2020 · Many different industries use High-Pressure boilers for central heating systems and many other applications. The water in boilers is used to produce steam which generates energy for other processes. High-pressure boilers require specialized care to operate. Do you think you have what it takes to operate them and understand their use? Take up this test to find …Get Price
Steam pressure reduction is the lowering of the steam pressure at the boiler plant by means of the pressure the boiler stack temperature varies linearly with steam pressure. A savings of 0.4% to 0.8% of the fuel input can be expected from lower stack temperature. For watertube boilers, radiation loss can be estimated using the American Get Price
The shell is heated by low-pressure (waste) steam at 0.4–0.5 MPa and at 160 °C, which condenses inside the inter-tube space. Brown coal with a particle size of less than 10 mm enters the tubes with a diameter of 100 mm on the upper side of the shell, passes through the tubes, and is dried to a 12–15% moisture content.Get Price
Residential Steam Boilers Normal Operating Pressure Residential steam heating systems are almost always designed to operate at very low pressures, perhaps around 0.2 to a maximum of 0.5 psi - that' s 1/2 of one psi.Get Price
Because the operating temperature, pressure, and form of heat distribution are different from hot water heat (typically 20-30 psi of hot water), steam boilers (typically less than 0.5 psi steam) use use controls that monitor steam pressure operated controls like the Honeywell steam pressure control shown below.Get Price
Boilers can be classified into the following configurations: Pot boiler or Haycock boiler/Haystack boiler A primitive "kettle" where a fire heats a partially filled water container from below. 18th century Haycock boilers generally produced and stored large volumes of very low-pressure steam, often hardly above that of the atmosphere.Get Price
* Steam capacities shown are saturated steam. Capacities will vary depending on conditions and limitations. Metric Conversions: inches x 25.4 = mm. inches x 2.54 = cm. feet x 0.3048 = m. lb/h x 0.000453 = T/h. lb/h x 0.000126 = kg/sGet Price
0-14 psi: 0-50 psi: 0-150 psi: 0-300 psi: 0-700 psi: 0-1,000 psi: 0-1,200 psi: 0.3 psi: 0.5 psi: These valves meet ASME Code Section I for use with steam power boilers requiring pressure relief above 15 psi. For use with low-pressure steam-heating boilers requiring pressure relief at 15 psi, these valves meet ASME Code Section IV. Fast Get Price
Steam Boilers Volume 1 / Page 5 . 2.1.10 The standard symbol for point of connection, new work to existing shall be used. A similar symbol with the circle entirely filled-in shall be used to indicate extent of demolition. 2.1.11 Dashed lines shall be used to distinguish material to be demolished.Get Price
Steam pressure reduction is the lowering of the steam pressure at the boiler plant by means of the pressure the boiler stack temperature varies linearly with steam pressure. A savings of 0.4% to 0.8% of the fuel input can be expected from lower stack temperature. For watertube boilers, radiation loss can be estimated using the American Get Price
pressure and medium pressure steam. Part-load . operation. Steam turbines have relatively good part-load performance, but . efficiency does decline as power output is reduced. Fuel Boilers are commonly used to generate steam required for steam . turbines, and boilers can utilize a wide range of fuels, including natural . gas, oil, coal, and Get Price
0-14 psi: 0-50 psi: 0-150 psi: 0-300 psi: 0-700 psi: 0-1,000 psi: 0-1,200 psi: 0.3 psi: 0.5 psi: These valves meet ASME Code Section I for use with steam power boilers requiring pressure relief above 15 psi. For use with low-pressure steam-heating boilers requiring pressure relief at 15 psi, these valves meet ASME Code Section IV. Fast Get Price
I have two BURNHAM ALPINE BOILERs which are located in sandwich Ma. (02563) Both are MODEL ALP150BW-2T02 installed in 2014 with the 5 year service plans (the boilers are not in the same building). These boilers are in a summer house (one in the house the other in the garage) this refers to the house boiler with hot water tank.Get Price
Pressure range of the boiler is about 0.7 MPa to 2 MPa and efficiency is 65 to 70%. Fuel in these boilers is added into the grate which heats the gases. Hot gases enter the front section of the boiler and leave the boiler from back and then enter the bottom flue and start moving to front section of boiler.Get Price
Oct 16, 2020 · Many different industries use High-Pressure boilers for central heating systems and many other applications. The water in boilers is used to produce steam which generates energy for other processes. High-pressure boilers require specialized care to operate. Do you think you have what it takes to operate them and understand their use? Take up this test to find …Get Price
Steam Boilers Volume 1 / Page 5 . 2.1.10 The standard symbol for point of connection, new work to existing shall be used. A similar symbol with the circle entirely filled-in shall be used to indicate extent of demolition. 2.1.11 Dashed lines shall be used to distinguish material to be demolished.Get Price
PROCESS DESIGN OF STEAM BOILERS (PROJECT STANDARDS AND SPECIFICATIONS) Page 8 of 45 Rev: 01 April 2011 i. The steam as measured at drum outlet shall have an impurity not greater than 0.02 mg/kg (ppm mass) silica. The wetness of the steam leaving the drum shall not exceed 0.02%. j. Heat release (maximum and average) per cubic meters of furnace Get Price
Steam Rankine cycle is known as one of the main power-generating cycles, which consists of four key devices, namely a boiler (heat exchanger), a steam turbine, a condenser (heat exchanger), and a pump, as illustrated in Fig. 28.This cycle needs heat input for the boiler either by burning fossil fuels, such as oil, coal, and natural gas, or by obtaining the necessary heat from renewable …Get Price
Feb 19, 2015 · There are a number of considerations to factor when determining the best boiler for your steam generation needs like operating pressure, steam pounds/hour output, demand fluctuation, general application requirments and total cost of ownership, etc. Two primary boiler types, the firetube boiler and the watertube boiler, are essentially opposite in design. The …Get Price
Residential Steam Boilers Normal Operating Pressure Residential steam heating systems are almost always designed to operate at very low pressures, perhaps around 0.2 to a maximum of 0.5 psi - that' s 1/2 of one psi.Get Price
The shell is heated by low-pressure (waste) steam at 0.4–0.5 MPa and at 160 °C, which condenses inside the inter-tube space. Brown coal with a particle size of less than 10 mm enters the tubes with a diameter of 100 mm on the upper side of the shell, passes through the tubes, and is dried to a 12–15% moisture content.Get Price