condensation in steam boiler
Capacity:1-20t/h
Rated thermal efficiency: 100-104%
Fixed working pressure: ≤1.6MPa
Applicable fuel:natural gas etc.
Capacity:0.7-14MW
Rated thermal efficiency:96-98%
Fixed working pressure:≤1.25MPa
Applicable fuel:Natural gas, light oil, etc.
Capacity:0.7-2.8Mw
Rated thermal efficiency: 97.2-106%
Fixed working pressure:0.1MPa
Applicable fuel:Natural gas, etc.
Capacity:2.8-7.0Mw
Rated thermal efficiency:≥105.5%
Fixed working pressure:-0.02MPa
Applicable fuel:Natural gas, etc.
Capacity:99Kw
Rated thermal efficiency:97.2-104.4%
Fixed working pressure:1.0MPa
Applicable fuel:Natural gas, etc.
Capacity:0.5-4.0 t/h
Rated thermal efficiency:98%
Fixed working pressure:≤1.25MPa
Applicable fuel:electric energy
Tips. Having said this, it is necessary to be mindful of the following when heating with saturated steam: Heating efficiency may be diminished if steam other than dry steam is used for process heating. Contrary to common perception, virtually all of the steam generated from a boiler is not dry saturated steam, but wet steam, which contains some non-vaporized water molecules.Get Price
May 02, 2000 · condensation occurs in systems where carbon dioxide is a problem. Keep in mind that the The impurities found in the makeup water will build up in the boiler as the water turns to steam leaving most impurities behind. There are known maximum limits for these impurities, which can and will be surpassed without proper blow down. Get Price
upon the ratio of boiler feedwater makeup to returned condensate and the operating pressure of the deaerator. Deaerators use steam to heat the water to the full saturation temperature corresponding to the steam pressure in the deaerator and to scrub out and carry away dissolved gases. Steam flow may be parallel, cross, or counter to the water flow.Get Price
The quantity of steam which the boiler generates, usually measured in kg/h. For selecting a blowdown system, the most important figure is usually the maximum quantity of steam that the boiler can generate at full-load. When the above information is available the required blowdown rate can be determined using Equation 3.12.5Get Price
upon the ratio of boiler feedwater makeup to returned condensate and the operating pressure of the deaerator. Deaerators use steam to heat the water to the full saturation temperature corresponding to the steam pressure in the deaerator and to scrub out and carry away dissolved gases. Steam flow may be parallel, cross, or counter to the water flow.Get Price
The function of the steam trap is to return the collected water in the steam pipe to the boiler due to partial condensation of steam. The steam is not allowed to escape and automatically returned to the boiler. Construction: A steam trap is a disc or short solid pipe nipple having a small hole.Get Price
Steam blanketing is a condition that occurs when a steam layer forms between the boiler water and the tube wall. Under this condition, insufficient water reaches the tube surface for efficient heat transfer. The water that does reach the overheated boiler wall is rapidly vaporized, leaving behind a concentrated caustic solution, which is corrosive.Get Price
concentrations, steam quality can be impaired. In addition, hardness salts can precipitate from the boiler water to form sludge and eventually scale, which deposits on the internal surfaces of the boiler. The result: a serious loss of boiler efficiency, and possibly boiler failure.Get Price
The successful operation of a steam heating system consists of generating steam in sufficient quantity to equalize building heat loss at maximum efficiency, expelling entrapped air, and returning all condensate to the boiler rapidly. Steam cannot enter a space filled with air or water at pressure equal to the steam pressure.Get Price
The quantity of steam which the boiler generates, usually measured in kg/h. For selecting a blowdown system, the most important figure is usually the maximum quantity of steam that the boiler can generate at full-load. When the above information is available the required blowdown rate can be determined using Equation 3.12.5Get Price
To maintain boiler integrity and performance and to provide steam of suitable turbine or process purity, boiler feedwater must be purified and chemically conditioned. The amount and nature of feedwater impurities that can be accommodated depend on boiler operating pressure, boiler design, steam purity requirements, type of boiler water internal treatment, blowdown rate, and …Get Price
The function of the steam trap is to return the collected water in the steam pipe to the boiler due to partial condensation of steam. The steam is not allowed to escape and automatically returned to the boiler. Construction: A steam trap is a disc or short solid pipe nipple having a small hole.Get Price
Steam is a compressible gas where pipe line mass flow capacity depends on steam pressure. Sizing Steam Pipes . Steam is a compressible gas where the capacity of a pipe line depends on the size of the pipe and the steam pressure. Soft or Hard Water . Carbonates dissolved in water. Steam Boiler Rating and Feed Water TemperatureGet Price
Related Topics . Steam Thermodynamics - Thermodynamics of steam and condensate applications; Related Documents . Boiler Capacity - Steam boilers output can be expressed in Boiler Horsepower, MBTU or in Pounds of Steam delivered per hour; Design of Steam Heating Systems - An introduction to the basic design of steam heating systems; Heating Systems - …Get Price
Steam Superheaters in Industrial Boilers. The Steam Superheater is a coil type heat exchanger which is used to produce superheated steam or to convert the wet steam to dry steam, generated by a boiler.. It is different from a boiler in a way that, boiler utilizes both sensible heat as well as latent heat to convert water into steam while superheater utilizes only sensible heat to …Get Price
Heat recovery steam generator is a high-efficiency steam boiler that uses hot gases from a gas turbine for reciprocating engine to generate steam in a thermodynamic Rankine Cycle. This system is able to generate steam at different pressure levels according to chemical process requirements ( PGTHERMAL, 2009 ).Get Price
Sep 09, 2007 · Undesired vacuum conditions may occur in vessels for working conditions such as steam generator / steam accumulator or steam heated tank / heat exchanger etc. or in accumulator of highly volatile liquid or for liquid under low vapor pressure conditions. Condensation will take place during shut down or due to change in temperature.Get Price
A steam boiler needs pumping energy to be able to insert feedwater to produce pressurized steam. The higher the pressure, the higher the own power demand (Table 3.3). vapour condensation in an external heat exchanger for the preheating …Get Price
concentrations, steam quality can be impaired. In addition, hardness salts can precipitate from the boiler water to form sludge and eventually scale, which deposits on the internal surfaces of the boiler. The result: a serious loss of boiler efficiency, and possibly boiler failure.Get Price
Steam Superheaters in Industrial Boilers. The Steam Superheater is a coil type heat exchanger which is used to produce superheated steam or to convert the wet steam to dry steam, generated by a boiler.. It is different from a boiler in a way that, boiler utilizes both sensible heat as well as latent heat to convert water into steam while superheater utilizes only sensible heat to …Get Price
The feed-water of the boiler is also fed to the steam drum through a feed pipe extending inside the drum, along the length of the steam drum. A steam drum is used without or in the company of a mud-drum/feed water drum which is located at a lower level. A boiler with both steam drum and mud/water drum is called a bi-drumGet Price
To maintain boiler integrity and performance and to provide steam of suitable turbine or process purity, boiler feedwater must be purified and chemically conditioned. The amount and nature of feedwater impurities that can be accommodated depend on boiler operating pressure, boiler design, steam purity requirements, type of boiler water internal treatment, blowdown rate, and …Get Price
On a steam boiler makeup water is needed frequently as steam heat systems always consume some water. Makeup water is provided either manually by a fill valve, using a sight glass, The porch radiator air vent was also replaced because of too much steam condensation in the room, but now the open/close valve is leaking at the base.Get Price
Inadequate insulation around the sterilizer or steam piping, allowing energy loss and condensation; Poorly controlled steam boiler chemistry (especially a deficiency of sulfites) Low sections of piping between the boiler and the sterilizer, allowing condensate to pool and be carried over with the steam entering the chamberGet Price
On a steam boiler makeup water is needed frequently as steam heat systems always consume some water. Makeup water is provided either manually by a fill valve, using a sight glass, The porch radiator air vent was also replaced because of too much steam condensation in the room, but now the open/close valve is leaking at the base.Get Price
May 02, 2000 · condensation occurs in systems where carbon dioxide is a problem. Keep in mind that the The impurities found in the makeup water will build up in the boiler as the water turns to steam leaving most impurities behind. There are known maximum limits for these impurities, which can and will be surpassed without proper blow down. Get Price
Fire-tube boiler Here, water partially fills a boiler barrel with a small volume left above to accommodate the steam (steam space).This is the type of boiler used in nearly all steam locomotives.The heat source is inside a furnace or firebox that has to be kept permanently surrounded by the water in order to maintain the temperature of the heating surface below the …Get Price
Heat from the furnace is added by the boiler, the superheater, and the reheater. Useful work is extracted from the steam by the high-pressure turbine (HPT) and the low-pressure turbine (LPT). Waste heat is rejected to the coolant in the condenser. Heat is also transferred from the extracted steam to the feedwater to improve thermal efficiency.Get Price
Fire-tube boiler Here, water partially fills a boiler barrel with a small volume left above to accommodate the steam (steam space).This is the type of boiler used in nearly all steam locomotives.The heat source is inside a furnace or firebox that has to be kept permanently surrounded by the water in order to maintain the temperature of the heating surface below the …Get Price
Gas and liquid service Working pressure: 6000 psig (413 bar) used as safety relief devices in steam applications such as ASME Boiler and Pressure Vessel Code Section I, Power Boilers. Weight, lb (kg) 1.7 (0.77) 5.7 (2.6) Set Pressure and Resealing PressureGet Price